SA6050 is a high-power power supply.
It is possible to customize to the user with an output voltage of 1000V and a maximum output current of 3000A.
The standard size size and built-in 4 1/2 LED display feature are easy for users to use.
Optional features allow remote control using the RS232 or RS485 interface.
Programmable DC Power Source
The regulation mode adopts Power module, which facilitates high efficiency,
high accuracy and high stavility.
The series can be made according to customer request,
with output volrage up to 2000V and output current up to 3000A.
Over Voltage Protection, Over Current Protection, Over Temperature Protection and
Over Load Protection keep the power supply and their load safe
from unexpected conditions.
For more complicated applications, the power supplies are available
with many optional functions
: RS232/485 interface, remote sensing, remote ON/OFF control, timer switch,
and
square waveform output.
The power supply is an ideal solution for various industrial applications.
Summary | |
Outputcapacity | 3KW/60V/50A |
Model | SP series |
Input | singlephase 220Vac±10% |
Constant Voltage Operation | |
Output voltage | DC 0~100% full range adjustable |
Line regulation | ≤ 0.2% + 2d |
Load regulation | ≤ 0.3% + 2d |
Temperature drift | 0.1%/ |
Ripple & Noise | ≤ 0.3%+10mV (rms) |
Constant Current Operation | |
Output Current | DC 0~100% full range adjustable |
Line regulation | ≤ 0.2% + 2d |
Load regulation | ≤ 0.3% + 2d |
Temperature drift | ≤ 0.3%/ |
Ripple & Noise | ≤ 0.5%+10mA (rms) |
Display | |
Meter | 4 digitsLED display |
Voltage display | 00.00V-99.99V; 000.0V-999.9V; 0000V-9999V |
Current resolution | 00.00A-99.99A; 000.0A-999.9A; 0000A-9999A |
Accuracy | ±1% (F.S) |
Protection | |
Over Voltage Protection (OVP) | Built-in OVP, protection limit is +5% of rated voltage. The output will be shutdown when OVP is activate |
Over Current Protection (OCP) | Over load, short circuit and current limit output |
Over Temperature Protection (OTP) | Built-in OTP, protection limit is 85℃±5% (temperature of cooling device). The output will be shutdown when OTP is acti |
General | |
Cooling method | Cooling fan |
Input module | Power socket or terminal block |
Operating environment | ℃0~40℃, 10%~80%RH |
Storage environment | ℃-20~70℃, 10%~90%RH |